Chromatic confocal displacement sensor
-
Chromatic confocal displacement sensor selection
-
Confocal 2D Profiler
-
Confocal 3D Profiler
-
Measurement Serise
-
Double head thickness gauge
-
Multilayer Thickness Gauge
-
Chromatic confocal without refractive index thickness gauge
-
Micro Interferometric Thickness Gauge
-
Interferometric thickness sensor
Measurement principle of chromatic confocal technology
Measuring principle of Chromatic confocal technique
Measure distance using wavelength information
A beam of polychromatic light (white) with a broad spectrum is emitted from the light source, and spectral dispersion occurs through the dispersive lens to form monochromatic light of different wavelengths. The focus of each wavelength corresponds to a distance value. When the measurement light hits the surface of the object and is reflected back, only the monochromatic light that meets the confocal conditions can be sensed by the spectrometer through the small hole. The distance value is obtained by calculating the wavelength of the sensed focal point
Specs/Probes
CDS-500 | OP1 | OP2 | OP3 | OP4 | OP4L | OP5 | OP6 | Pro4 | Pro5 | |||
Working Distance | mm | 8 | 11 | 15 | 24 | 29 | 37 | 204 | 24 | 67 | ||
Range | μm | ±55 | ±190 | ±600 | ±1850 | ±2000 | ±5500 | ±5000 | ±2000 | ±5000 | ||
Angular Characteristics | deg | ±45° | ±28° | ±29° | ±21° | ±19° | ±14° | ±7.5° | ±45° | ±16.5° | ||
Amplifier Model | Fc | Fc | Fc | Fe | Fd | Fd | Fe | Fd | Fc | Fc | Fd | |
Light Spot Size | μm | 2 | 10 | 11 | 20 | 12 | 22 | 40 | 24 | 36 | 15 | 45 |
Displacement measurement | ||||||||||||
Resolution | nm | 2(8) | 5(20) | 10(40) | 20(80) | 20(80) | 24(94) | 150(600) | 150(600) | 500(1000) | 20(80) | 150(600) |
Accuracy | ±0.02%F.S. (F.S.=Span) | |||||||||||
Thickness measurement | ||||||||||||
Minimum Thickness Measurement | μm | 5 | 12 | 22 | 66 | 66 | 78 | 192 | 192 | 200 | 66 | 192 |
Maximum Thickness Measurement | μm | 100 | 511 | 1694 | 5500 | 5500 | 5998 | 17078 | 17078 | 16500 | 5665 | 13514 |
Length | mm | 208 | 176 | 176 | 130.5 | 145.5 | 145.5 | 130.5 | 145.5 | 180 | 261 | 241 |
Weight | kg | 0.49 | 0.30 | 0.40 | 0.23 | 0.25 | 0.25 | 0.25 | 0.25 | 0.6 | 1.62 | 1.38 |
Diameter | mm | 27/40 | 27 | 27/32 | 27 | 27 | 27 | 27 | 27 | 27/65 | 27/93.4 | 27/56 |
Specifications/Controllers
Model | CDS-500 |
Sampling Frequency | 200 to 4500 points/sec user definable |
Light source | Blue Laser |
Measurement Mode | Displacement/Thickness |
Communication Control | Ethernet |
Encoder | Incremental (A/B items) |
Synchronous I/O | 1 Trigger input(TTL)5V |
Fiber Connector | FC/APC |
Compatibility | Compatible with all probe models |
Power/Power | 24V DC 3A |
Operating Temperature | 5℃-40℃ |
Storage Temperature | -30℃-70℃ |
Relative Humidity | 5%-80% non-condensing |
Protection Level | IP 40 |